Standard models are available in a range of sizes, starting from small desktop units which are roughly the size of 60 x 40 x 40 cm, and extending to larger units which are about 120 x 60 x 80 cm based on what you need them for.
This refers to assessing samples with a specific color and maintaining the same alloted time interval on all parameters to ensure neutrality of variables and reproducibility of lightness in the color.
Yes, we warmly welcome and sincerely invite you or your team to visit our factory, we will help to arrange hotel and pick up you from airport.
To extend the life of a haze meter, keep the instrument dust-free and clean, regularly calibrate it, and control for a stable dry storage. For better results, avoid letting the optics dry, and leave the meters under sunlight. For optimal performance, have the meter professionally serviced once a year.
A gloss test gauges the reflective quality of a surface by casting light at a fixed angle and measuring the amount reflected. It defines the level of shine or dullness of a surface, and it is very crucial in coatings, automotive, and product finishing
Zero calibration of a hazemeter is a critical pre-measurement procedure to ensure the instrument’s accuracy by resetting its baseline to "zero" when no haze or light attenuation is present.
Align the hazemeter’s measurement window with air or a black background, ensuring no objects block the window.
Press the hazemeter’s zero calibration button and wait for the instrument to complete automatic calibration. At this point, the instrument should display a zero haze value and a zero light transmittance value.
Observe the instrument’s display to confirm the zero calibration result stabilizes near zero. If the zero calibration is inaccurate, repeat the above steps multiple times until the displayed haze and light transmittance values stabilize near zero.
Perform 0-degree calibration before testing, this eliminates inherent instrument drift, environmental interference, or residual signal errors, ensuring subsequent measurements of transparent/translucent samples (e.g., plastic films,pvc, glass, coating, displays and cosmetic packaging) are reliable. Correct for minor instrument deviations caused by long-term use, temperature changes, or power fluctuations.
Inquiry - quotation - communication - order confirming - deposit payment - production - testing and debugging - balance payment - packing - delivery - customer receiving - after service.
Every 2,000 - 3,000 hours or manufacturer recommendation to maintain consistent light and color quality.
Use our 3nh company approved light. Replace all of the same type together and recalibrate to keep consistent color rendering. We usually do not recommend customers to modify it themselves, as this can affect the accuracy of the color and cause unnecessary losses
Take L*a*b* readings of two samples using a colorimeter or spectrophotometer and calculate color difference using the 3 formula (Delta E). The difference in 0 is the reported Delta-E, which shows how visible the change is, whereas the thresholds define the acceptability as per the application requirements.