Call Now
ST10 is a new portable spectrocolorimeter with 3nh own core research and development technology.
It is easy to use and can be measured with one click. It uses a built-in large area silicon photodiode array sensor. It has excellent repeatability and inter-station difference, the measured data are steady, accurate and reliable.
ST10 spectrocolorimeter with Φ8MM/φ10mm platform measuring aperture, in plastic electronics, paint coating, textile printing and dyeing, printing paper products, automotive, medical, cosmetics and food industries, scientific research institutions, laboratories are widely used.
Characteristics of the array spectrocolorimeter ST10
1.Silicon photodiode array sensor
The larger array sensor, the stronger light will not be saturated, the lower light sensitivity is higher and the wider spectrum response range, has guaranteed the instrument measurement speed, the accuracy, the stability and the consistency, grasps the core technology, with the same platform of international standards, achieve perfect compatibility.
2.Adopt full waveband balanced LED light source
ST10 spectrocolorimeter adopts 400 ~ 700nm full waveband balanced LED light source as the illumination light source, which has enough spectrum distribution in the visible light range and avoids the loss of the spectrum of white LED in the specific wave band.
3.Grating splitting technology
The use of plane grating spectroscopy technology, with a higher resolution, so that more accurate color measurement.
4.Intelligent base, automatic calibration
It is equipped with intelligent calibration base, can carry out automatic white board calibration, professional grade standard white board reflectivity R% ≥95% , good surface uniformity, high stability, can obtain repeated accurate data.
5.New fashion appearance design based on ergonomics
The hand-held position and the position of the measuring button are carefully designed to meet different holding habits, smooth and fine surface, derived from the professional appearance treatment technology.
6.Excellent interstation and repeatability
The repeatability ΔE * ab ≤0.05, the Inter-instrument Error ΔE * AB ≤0.4 data is stable and reliable, which ensures the consistency of the data measured by multiple devices, and can be used for color matching and accurate color transfer.
7.Color management software
The array spectrocolorimeter ST10 is equipped with SQCX software, which is suitable for quality monitoring and color data management in various industries. The user's color management data, compare color differences, generate test reports, provide a variety of color space measurement data, customized customer color management.
ST10 technical parameters of the spectrocolorimeter
Product name | ST10 spectrocolorimeter |
Optical Geometry | D/8(diffused illumination, 8-degree viewing angle) |
Specular Component | SCI Including the specular reflection of light |
Meet The Criteria | CIE NO.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7 |
Repeatability* | ΔE*ab≤0.05 |
Inter-instrument Error** | ΔE*ab≤0.4 |
Displayed Accuracy | 0.01 |
Measuring/Illuminating Aperture*** | Dual Apertures:Φ8MM/φ10mm platform + Φ8MM/φ10mm tip |
Measurement Indicators | Spectral reflectivity, CIE-Lab, CIE-LCh, HunteLab, CIE-Luv, XYZ, Yxy, RGB, chromatic aberration (ΔE * ab, ΔE * CMC, ΔE * 94, ΔE * 00) , whiteness (ASTM E313-00, ASTM E313-73, CIE/ISO, AATCC, Hunter, Taube Berger Stensby) , yellows (ASTM D1925, ASTM E313-00, ASTM E313-73) ,staining fastness, color-changing fastness, etc. (some of the indicators were achieved by PC) |
Illuminant | D65,A,C,D50,F2,F7,F11 |
Displayed Data | Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Simulation, Color Offset |
Light Source | Combined full spectrum LED light source |
Locating Method | Stability film, visual |
Calibration | Intelligent automatic calibration (Contact Type) |
Observer Angle | 2°,10° |
Integrating Sphere Size | 40mm |
Spectrophotometric Mode | Flat Grating |
Sensors | Large-area silicon photodiode array ( double-row 20 group) |
Wavelength Interval | 10nm |
Wavelength Range | 400-700mm |
Measured Reflectance Range | 0-200% |
Reflectivity resolution | 0.01% |
Measurement Mode | Single Measurement, Average Measurement(2-99times) |
Measuring Time | About 1s |
Size | L * W * H=114 X 70 X 208mm |
Weight | About 435g(Calibration block not included) |
Battery | Li-ion battery, 8500 measurements within 8 hours |
Illuminant Life Span | 10 years, more than 1.5 million times measurements |
Display | 3.5-inch TFT color LCD, Capacitive Touch Screen |
Data Port | USB |
Data Shorage | Standard 500 Pcs, Sample 10000 Pcs, Mass storage on PC side |
Software Support | Windows |
Language | Simplified Chinese, English, Traditional Chinese |
Operating Environment | 0~40℃, 0~85%RH (no condensing), Altitude < 2000m |
Storage Environment | -20~50℃, 0~85%RH (no condensing) |
Standard Accessory | Power Adapter, USB Cable, User Guide, PC Software(Download from office website), White and Black Calibration Cavity, Protective Cover, Wrist strap, 8mm flat aperture, 4mm tip aperture |
Optional Accessory | USB Micro Printer, Powder Test Box |
Notes: * 30 standard deviations of the whiteboard were measured at a 5-second interval after whiteboard calibration; ** BCRA Series II 12-panel measurement average; *** The illumination aperture is the actual aperture size of the instrument; If there are any changes to the above parameters, without prior notice. |